logo

Detalles de los productos

Created with Pixso. Hogar Created with Pixso. Productos Created with Pixso.
Banco de ensayo del medidor fijo
Created with Pixso.

High-Precision Meter Test Bench for Accurate Electric Meter Calibration

High-Precision Meter Test Bench for Accurate Electric Meter Calibration

Nombre De La Marca: GENY
Número De Modelo: Yc1893d
Cuota De Producción: 1 PCS
Precio: Negociable
Condiciones De Pago: L/C, T/T, D/P
Capacidad De Suministro: 30 pcs por mes
Información detallada
Lugar de origen:
China.
Certificación:
ISO, CE
Uso:
Medidor de energía multifuncional, medidor de vatios-hora, medidor para uso industrial y doméstico,
Rango de voltaje de salida:
24V a 288V
Teoría:
Metro electrónico
Rango de corriente de salida::
1 mA a 120A (hasta 230A Max)
Detalles de empaquetado:
caja de madera contrachapada
Capacidad de la fuente:
30 pcs por mes
Resaltar:

electric meter calibration test bench

,

stationary meter test equipment

,

high-precision meter calibration bench

Descripción de producto

High-Precision Meter Test Bench for Accurate Electric Meter Calibration


Key Features


  • Accurate measurement of active/reactive power and energy

  • Supports start-up and no-load (creep) testing

  • Automatic marking for fast and efficient tests

  • Error analysis: basic error, average error, standard deviation, 24-hour drift

  • Tests voltage, frequency, harmonic (2nd-21st), and phase sequence effects

  • Simultaneous current testing for multiple meters on one rack

  • Non-disconnect testing for voltage and current circuits

  • Built-in protection for current open-circuit and voltage short-circuit

  • Integrated optical scanner to improve efficiency

  • Motorized and manual operation modes

  • PC software for data processing, storage, and report generation

  • Barcode input support

  • Durable mechanical design

  • Configurable from 3 to 60 meter positions


Specifications


  • Input Voltage: AC 220V ±10%, 50Hz ±2Hz

  • Operating Temperature: -10°C to +40°C

  • Operating Humidity: 35% to 95%

  • Output Voltage Range: 24V to 288V

  • Maximum Output Voltage Power: 1000VA

  • Voltage Resolution: 0.01%

  • Voltage Stability: 0.02% per 120 seconds

  • Load Variation Rate: 0.01%

  • Voltage Distortion: ≤0.3% (full linear load range)

  • Output Current Range: 1mA to 120A (up to 230A max)

  • Maximum Output Current Power: 2000VA

  • Current Resolution: 0.01%

  • Current Stability: 0.02% per 120 seconds

  • Load Variation Rate: 0.01%

  • Current Distortion: ≤0.3% (full linear load range)

  • Continuous Current: 100A

  • Phase Adjustment Range: 0° to 360°

  • Phase Resolution: 0.01°

  • Frequency Adjustment Range: 45Hz to 65Hz

  • Frequency Resolution: 0.01Hz

  • Power Output Stability: 0.02% per 120 seconds



High-Precision Meter Test Bench for Accurate Electric Meter Calibration 0


High-Precision Meter Test Bench for Accurate Electric Meter Calibration 1